Main feature
(A) three protection
1) Over-temperature protection: When the maximum value of the actual temperatures of the hot zone exceeds the set overtemperature protection device automatically turns off the instrument each heating zone power, while the alarm in order to avoid accidents.
2) over-current protection: When working at TCD detector, such as current set too high or TCD sudden increase in resistance, overcurrent protection device automatically turns off the TCD bridge current, and alarm and display OVER TCD to protect the tungsten being burned (if the user due to operational errors, start TCD in the absence of carrier gas, the device can automatically cut off power to protect the tungsten filament). Also increase the amplification circuit, in order to increase sensitivity.
3) crash protection: instrument at work, when a short circuit occurs thermal element heating zone, when the circuit, the heating wire on the ground, the computer operating system crashes and so on, the instrument can automatically cut off power and alarm, to avoid further work accidents . The above three points protection feature allows you to analyze more safe and secure work.
(B) six Thermostat
GC1690 gas chromatograph capable of six-way thermostat, which AUX1 control external heating devices, column temperature and AUX1 with fifth-order temperature programming.
(C) pneumatic control
Pneumatic controller with external capillary gas line box, gas assist gas manifold box placed separately, air ratio adjustment intuitive, flexible control, and once a manifold problems can instantly switch had no effect on the host operating, maintenance Convenience.
(Iv) noise
Hosts in each blade using a mold forming, symmetry, avoid imbalance generated noise during operation.
(E) flexible configuration
Capillary injector independent, you can configure dual capillary injector according to user requirements of the dual amplifier board to install two capillary column; you can also install two packed column; you can also install a packed column and a capillary column; also can increase the flexibility TCD, FPD, NPD, ECD detector based on this analysis to meet different requirements; an instrument can install up to three injectors and three detectors.
(Vi) appearance
With a vertical oven, nice shape, and small footprint, suitable for laboratory use small space, the new back-pressure valve using a split / splitless mode.
(Vii) pneumatic controller
Pneumatic controller with external, single or dual capillary gas line box, single or dual carrier gas path box, single or dual gas assisting gas manifold box placed separately, air ratio adjustment intuitive, flexible control, you can select the most appropriate combination of flow controller based on an analysis purposes.
(Viii) monitor / keyboard
GC1690 display information-rich, simple keyboard, bright backlit LCD display for easy reading, easy to understand Chinese keyboard, reducing the burden on the operator. Green button for the temperature control series; blue button for the detector parameter control series; the white keys of the numeric keys series; black keys to control external events series.
(Ix) detector (DET)
Can be installed at the same time in any three of the following detectors:
FID flame ionization detector
TCD thermal conductivity detector
FPD flame photometric detector
NPD NPD
ECD electron capture detector
(X) injector
1) packed column on column
2) Split / splitter no injection
3) large-diameter capillary WBC injection
4) packed column steam sample
5) The six-way valve gas into style
(Xi) Oven
Use get recognized high performance column oven large gasification chamber considering the heat radiation generated by heating or detector, column compartment is designed to erect the structure, the maximum temperature can reach 420 ℃, temperature range + 7 ℃ ~ 420 ℃, 5 stage temperature programming, automatic back door, you can set the height of the temperature within 420 ℃, 450 ℃ fixed independent protection circuit, with dual protection structure.
Main Specifications
Column Oven
Temperature range
RT + 7 ℃ ~ 420 ℃
Temperature Accuracy
Better than ± 0.1 ℃
Internal volume
240 × 160 × 360
Program order
5 Order
Heating rate
0.1 ~ 39.9 ℃ / min arbitrarily set
Warm-up time
0 ~ 665min (increment 1min)
Technical Parameters
Index
Detector
Sensitivity or acuity sense
Drift
Noise
The linear range
Hydrogen flame (FID)
Mt≤1 × 10-11g / s
≤1 × 10-12 (A / 30min)
≤2 × 10-13A
≥106
Thermal conductivity (TCD)
S≥2000mV. M1 / mg
≤0.1 (mV / 30min)
≤0.01mV
≥106
Flame (FPD)
P≤2 × 11-12g / s
S≤5 × 10-11g / s
≤4 × 10-11 (A / 30min)
≤2 × 10-11A
P ≥103
S ≥102
Nitrogen (NPD)
N≤1 × 10-12g / s
P≤5 × 10-11g / s
≤2 × 10-12 (A / 30min)
≤4 × 10-13A
≥103
Electron capture (ECD)
≤2 × 10-13g / ml
≤50 (uV / 30min)
≤20uV
≥103
Quote list
Inventory name
Specifications Model
Unit
Reference Price
Gas Chromatograph
GC1690F (double PIP + Dual FID)
Taiwan
Negotiable
Gas Chromatograph
GC1690F (J) (single FID + SPL)
Taiwan
Negotiable
Gas Chromatograph
GC1690F (S) (single PIP + single FID)
Taiwan
Negotiable
Gas Chromatograph
GC1690T (S) (single PIP + TCD)
Taiwan
Negotiable
Gas Chromatograph
GC1690T (double PIP + TCD)
Taiwan
Negotiable
Gas Chromatograph
GC1690T (double PIP + TCD + gas injection)
Taiwan
Negotiable
Gas Chromatograph
GC1690J (Dual FID + Dual PIP + SPL)
Taiwan
Negotiable
Gas Chromatograph
GC1690J (S) (Dual FID + single PIP + SPL)
Taiwan
Negotiable
Gas Chromatograph
GC1690A (Dual FID + TCD + Dual PIP + SPL)
Taiwan
Negotiable
Gas Chromatograph
GC1690B (Dual FID + Dual PIP + TCD)
Taiwan
Negotiable
Gas Chromatograph
GC1690B (FID + Dual PIP + TCD + dual gas injector + Reformer)
Taiwan
Negotiable
Gas Chromatograph
GC1690C (Dual FID + Dual PIP + SPL + dual enlarged board)
Taiwan
Negotiable
Gas Chromatograph
GC1690G (Dual FID + Dual PIP + dual enlarged board)
Taiwan
Negotiable
Gas Chromatograph
GC1690Q (Dual FID + double SPL + single enlarged board)
Taiwan
Negotiable
Gas Chromatograph
GC1690N (Dual FID + double SPL + dual enlarged board)
Taiwan
Negotiable
Gas Chromatograph
GC1691F (double PIP + Dual FID)
Taiwan
Negotiable
Gas Chromatograph
GC1650J (thermostat + single FID + SPL)
Taiwan
Negotiable
Gas Chromatograph
GC1650F (thermostat + single PIP + single FID)
Taiwan
Negotiable
Gas Chromatograph
GC1650T (thermostat + single PIP + TCD)
Taiwan
Negotiable
Gas Chromatograph
GC1650TF (thermostat + Dual PIP + TCD + single FID)
Taiwan
Negotiable
Gas Chromatograph
GC1650E (thermostat + single PIP + ECD)
Taiwan
Negotiable
Gas Chromatograph
GC1650E (J) (thermostat + single SPL + ECD)
Taiwan
Negotiable
Gas Chromatograph
GC1650P (thermostat + single PIP + FPD)
Taiwan
Negotiable
Gas Chromatograph
GC1650P (J) (thermostat + single SPL + FPD)
Taiwan
Negotiable
Gas Chromatograph
GC1650S (thermostat + single PIP + NPD)
Taiwan
Negotiable
Gas Chromatograph
GC1650S (J) (thermostat + single SPL + NPD)
Taiwan
Negotiable
Gas Chromatograph
GC1690E (Cheng L + single PIP + ECD)
Taiwan
Negotiable
Gas Chromatograph
GC1690E (J) (Cheng L + single SPL + ECD)
Taiwan
Negotiable
Gas Chromatograph
GC1690P (Cheng L + single PIP + FPD)
Taiwan
Negotiable
Gas Chromatograph
GC1690P (J) (Cheng L + single SPL + FPD)
Taiwan
Negotiable
Gas Chromatograph
GC1690S (Cheng L + single PIP + NPD)
Taiwan
Negotiable
Gas Chromatograph
GC1690S (J) (Cheng L + single SPL + NPD)
Taiwan
Negotiable
Gas Chromatograph
GC1690D (Cheng L + Dual PIP + FID + FPD)
Taiwan
Negotiable
Gas Chromatograph
GC1690D (J) (Cheng L + Dual PIP + SPL + FID + FPD)
Taiwan
Negotiable
Gas Chromatograph
GC1690DJJ (Cheng L + double SPL + FID + FPD)
Taiwan
Negotiable
Gas Chromatograph
GC1690K (Cheng L + Dual PIP + FID + ECD)
Taiwan
Negotiable
Gas Chromatograph
GC1690K (J) (Cheng L + Dual PIP + SPL + FID + ECD)
Taiwan
Negotiable
Gas Chromatograph
GC1690KJJ (Cheng L + double SPL + FID + ECD)
Taiwan
Negotiable
Gas Chromatograph
GC1690R (Cheng L + Dual PIP + FID + NPD)
Taiwan
Negotiable
Gas Chromatograph
GC1690R (J) (Cheng L + Dual PIP + SPL + FID + NPD)
Taiwan
Negotiable
Gas Chromatograph
GC1690RJJ (Cheng L + double SPL + FID + NPD)
Taiwan
Negotiable
Gas Chromatograph
GC1690ENJJ (Cheng L + double SPL + ECD + NPD)
Taiwan
Negotiable
Gas Chromatograph
GC1690EPJJ (Cheng L + double SPL + ECD + FPD)
Taiwan
Negotiable
Gas Chromatograph
GC1690L-1 (Cheng L + Dual PIP + SPL + FID + FPD + ECD)
Taiwan
Negotiable
Gas Chromatograph
GC1690L-2 (L + drive double PIP + SPL + FID + NPD + ECD)
Taiwan
Negotiable
Gas Chromatograph
GC1690L-3 (Cheng L + single PIP + double SPL + FID + ECD + FPD)
Taiwan
Negotiable
Gas Chromatograph
GC1690L-4 (Cheng L + single PIP + double SPL + FID + ECD + NPD)
Taiwan
Negotiable
Gas Chromatograph
GC1690L-5 (Cheng L + 3 * SPL + FID + ECD + FPD)
Taiwan
Negotiable
Gas Chromatograph
GC1690L-6 (Cheng L + 3 * SPL + FID + ECD + NPD)
Taiwan
Negotiable
Electron Capture Detector
GC1690-ECD
Taiwan
Negotiable
Flame photometric detector
GC1690-FPD
Taiwan
Negotiable
NPD
GC1690-NPD
Taiwan
Negotiable
Thermal conductivity detector
GC1690-TCD
Taiwan
Negotiable
Hydrogen flame ionization detector
GC1690-FID (Dual FID)
Taiwan
Negotiable
Remark
The above table Code Meaning: FID ----- hydrogen flame ionization detector thermal conductivity detector TCD ---- ECO ----- electron capture detector PIP ---- packed column inlet SPL-- - Split / Splitless Inlet